Filter brands
Brands
Compare blood pressure monitors
Showing all 16 products
0 products shortlisted
Cost
Price
$135
$83
$72
$60
$99
$310
$170
$299
$140
$249
$175
$304
$99
$89
$249
$106
Cuff price - small
$27
$27
$28
Not stated
Not stated
Not stated
One size only
Not stated
$43
$43
$43
Not stated
Not stated
$45
$16
One size only
Cuff price - medium
$27
$27
$28
Not stated
Supplied
Supplied
Supplied
Supplied
$43
$43
$43
Supplied
Supplied
$45
$16
Supplied
Cuff price - large
$33
$33
$33
Not stated
Not stated
Not stated
One size only
Not stated
$43
$43
$43
Not stated
Not stated
$45
$16
One size only
Type
Type
Arm
Arm
Arm
Arm
Arm
Arm
Arm
Wrist
Arm
Arm
Arm
Arm
Arm
Arm
Arm
Wrist
Recommended products
Recommended
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Test results
CHOICE Expert Rating
Medaval rating
Accuracy score
Ease of use score
Operating score
Comfort score
Screen quality score
Information score
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Comments
Good points
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Bad points
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Features
Blood pressure
Heart rate
Irregular heartbeat display
Yes (in App)
Yes (in App)
Irregular heartbeat explained
Hypertension display
No - but has outside range warning
No (App only)
Yes (in App)
Yes (in App)
Hypertension explained
Troubleshooting help
Maintenance details
Adult suitability only
Not stated
Not stated
Not stated
Not stated
Not stated
Not stated
Not stated
Automatic power-off
Yes, after 1 minute
1
Yes, after 1 minute
Yes, after 1 minute
Yes, after 5 minutes
Yes, after 1 minute
Yes, after 1 minute
Yes, after 2 minutes
Yes, after 2 minutes
Yes, after 2 minutes
Yes, after 2 minutes
Yes, after 2 minutes
Yes, after 1 minute
Yes, after 2 minutes
1
1
Can operate from mains power
Yes, adapter sold separately
Yes, adapter sold separately
Yes, adapter sold separately
Yes, adapter sold separately
Yes, adapter sold separately
Yes, adapter supplied
Yes, adapter sold separately
Yes, adapter sold separately
Yes, adapter sold separately
Yes, adapter sold separately
Low battery indicator
Yes (in App)
Time
No (App only)
Yes (in App)
Yes (in App)
Date
No (App only)
Yes (in App)
Yes (in App)
Time and date
NA
Yes (alternate)
NA
Yes (alternate)
NA
Yes (in App)
Yes (in App)
Alarm
Computer interface
App based program, on smart device
App based program, on smart device
App based program, no display on monitor itself
App based program
Specifications
Validated
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Member only
Items supplied
Blood pressure monitor, 4 AA batteries, arm cuff with hose, carry case
Blood pressure monitor, 4 AA batteries, arm cuff with hose
Blood pressure monitor, 4 AA batteries, arm cuff with hose, carry case
Blood pressure monitor, 4 AA batteries, arm cuff with hose, carry case
Blood pressure monitor, 4 AAA batteries, arm cuff with hose
Blood pressure monitor, 4 AA batteries, arm cuff with hose, carry bag
Blood pressure monitor, 4 AA batteries, arm cuff with hose, carry case, blood pressure diary, adapter, PC cable, BPA software CD
Blood pressure monitor, 2 AAA batteries, carry case
Blood pressure monitor, 4 AA batteries, arm cuff with hose
Blood pressure monitor, 4 AA batteries, arm cuff with hose, carry case
Blood pressure monitor, 4 AA batteries, arm cuff with hose, carry case, digital thermometer (MC-245)
Blood pressure monitor with built-in arm cuff, 4 AAA batteries
Blood pressure monitor, 4 AA batteries, arm cuff with hose, carry bag
Blood pressure monitor, 4 AA batteries, arm cuff with hose
Blood pressure monitor, USB cable, carry case
Blood pressure monitor, USB cable, hard case
Batteries
4 x AA
4 x AA
4 x AA
4 x AA
4 x AAA
4 x AA
4 AA
2 x AAA
4 x AA
4 x AA
4 x AA
4 x AAA
4 x AA
4 x AA
Li-ion
Li-ion
Blood pressure range
0 - 299
0 - 299
40 - 279
40 - 260
0 - 299
0 - 300
30 - 280
40 - 260
0 - 299
0 - 299
0 - 299
40 - 260
40 - 279
0 - 299
40 - 260
40 - 260
Claimed accuracy
+/- 3 mmHg
+/- 3 mmHg
+/- 3 mmHg
+/- 3 mmHg
+/- 3 mmHg
+/- 3 mmHg
+/- 3 mmHg
+/- 3 mmHg
+/- 3 mmHg
+/- 3 mmHg
+/- 3 mmHg
+/- 3 mmHg
+/- 3 mmHg
+/- 3 mmHg
+/- 3 mmHg
+/- 3 mmHg
Measuring uncertainty
Not stated
Not stated
Not stated
Not stated
Not stated
Not stated
Not stated
Not stated
Not stated
Not stated
Not stated
Not stated
Not stated
Not stated
Not stated
Not stated
Pulse range
40 - 180
40 - 180
40 - 180
40 - 180
40 - 180
30 - 240
40 - 200
40 - 180
40 - 180
40 - 180
40 - 180
40 - 180
40 - 180
40 - 180
40 - 180
40 - 180
Recommended minimum time between measurements (min)
3 min
3 min
3 min
1 - 1.5 min
2-3 min
None stated
15 seconds
2 - 3 min
3 min
3 min
2-3 min
2 - 3 min
3 min
2-3 min
1 - 1.5 min
1 - 1.5 min
Other data displayed
Error for systolic/diastolic within 10 mmHg, movement during measurement, no pressure, cuff not applied correctly, no pulse and monitor internal error
Error for systolic/diastolic within 10 mmHg, movement during measurement, no pressure, cuff not applied correctly, no pulse and monitor internal error
Error for systolic/diastolic within 10 mmHg, movement during measurement, no pressure, cuff not applied correctly, no pulse, and monitor internal error
Error for unstable pressure, no systolic/diastolic pressure, pneumatic system blocked/leaked or cuff too tight/loose, cuff pressure over 300 mmHg, cuff pressure over 15 mmHg for over 3 min., and monitor internal error.
Error for movement during measure, air plug disconnected, arm cuff not applied correctly, clothing interfering with cuff, and air leaking from cuff (all 5 same error message), cuff not inflated sufficiently, cuff pressure too high (over 299 mmHg), and device error
Error for no pressure, movement during pressurization or exhaust, cuff leakage during pressurization or exhaust, blood pressure / pulse signal too weak, cuff pressure exceeds 300 mm Hg, adaptor error, and internal error
Error for weak pulse signal, movement during measurement, no pressure, abnormal result, pulse or cuff pressure too high, pulse too low and erros during MAM mode
Error for air plug disconnected, wrist cuff not applied correctly, air leaking from cuff (all 3 same error message), movement during measurement and cuff not inflated sufficiently, cuff pressure too high (over 299 mmHg), movement during measurement, clothing interfering with cuff, pulse not detected correctly, unable to connect to smart device or transfer data correctly, and device error, position indicator (wrist in correct position for measurement)
Error for air plug disconnected, arm cuff not applied correctly, air leaking from puff (all 3 same error message), movement during measurment and cuff not inflated sufficiently, cuff pressure too high (over 299 mmHg), movement during measure, clothing interfering with cuff, and device error
Error for air plug disconnected, arm cuff not applied correctly, air leaking from puff (all 3 same error message), movement during measurment and cuff not inflated sufficiently, cuff pressure too high (over 299 mmHg), movement during measure, clothing interfering with cuff, and device error
Error for air plug disconnected, arm cuff not applied correctly, air leaking from cuff (all 3 same error message), movement during measurement and cuff not inflated sufficiently, cuff pressure too high (over 299 mmHg), clothing interfering with cuff, and device error
Error for arm cuff not applied correctly, cuff pressure exceed max limit, movement during measurement, clothing interfering with cuff, and device error
Error for systolic/diastolic within 10 mmHg of each other, movement during measurement, no pressure (same error code for all 3), cuff not applied correctly, pulse not detected correctly, and device internal error
Error for air plug disconnected, arm cuff not applied correctly, air leaking from cuff (all 3 same error message), movement during measurement and cuff not inflated sufficiently, cuff pressure too high (over 299 mmHg), movement during measure, clothing interfering with cuff, and device error
Error for pressure outside measurement range, movement during measurement, cuff not inflated properly, irregular heartbeat, and cuff not properly applied
Error for unstable pressure system, no systolic/diastolic pressure, pneumatic system blocked/leaked or cuff too tight/loose, cuff pressure over 300 mmHg, cuff pressure over 15 mmHg for over 3 min., and monitor internal error.
Data stored
Last 90 readings and average (All, AM, PM)
Last 30 readings and average (All)
Last 60 readings
Last 60 readings
Last 14 readings
Last 100 readings
Last 200 readings
Last 100 readings
Last 30 readings
Last 90 readings and average (3 within 10 min)
Last 90 readings and average (3 within 10 min)
NA
Last 90 readings
Last 1 reading
(Depends on phone)
(Depends on phone)
Number of users that can store data
1
1
1
2
1
2
1
2
1
1
1
NA
1
1
Not applicable
Not applicable
Number of readings stored
90
30
60
120
14
200
200
200
30
90
90
NA
90
1
Not stated
Not stated
Origin
China
China
China
China
Vietnam
Korea
China
Vietnam
Vietnam
Vietnam
Vietnam
Japan
China
Vietnam
China
China
Website
Related products
Availability
Tested model
Tested model
Tested model
Tested model
Tested model
Tested model
Tested model
Tested model
Tested model
Tested model
Tested model
Tested model
Tested model
Tested model
Tested model